BrowseBrowse by Category
Browse by Category
Switch - side to side airflow - rack-mountable - with 2 x Line Card, Catalyst 9600X SUP-2, Cisco DNA Advantage
Main Specifications | |
---|---|
Product Description | Cisco Catalyst 9606R chassis - switch - rack-mountable - with 2 x Line Card, Catalyst 9600X SUP-2, Cisco DNA Advantage |
Device Type | Switch - with 2 x Line Card, Catalyst 9600X SUP-2, Cisco DNA Advantage |
Enclosure Type | Side to side airflow rack-mountable 8U |
Performance | Switching capacity: up to 25.6 Tbps ¦ Bandwidth per slot: 6.4 Tbps |
Features | Fan tray |
Power | AC 90-140/180-264 V (47 - 63 Hz) |
Power Redundancy | Optional |
Dimensions (WxDxH) | 17.4 in x 16.1 in x 13.9 in |
Manufacturer Warranty | Limited lifetime warranty |
General | |
Device Type | Switch - with 2 x Line Card, Catalyst 9600X SUP-2, Cisco DNA Advantage |
Enclosure Type | Side to side airflow rack-mountable 8U |
Performance | Switching capacity: up to 25.6 Tbps ¦ Bandwidth per slot: 6.4 Tbps |
Features | Fan tray |
Expansion / Connectivity | |
Expansion Slots | 2 (total) / 4 (free) x line-card slot ¦ 1 (total) / 2 (free) x supervisor slot |
Installed Modules Qty (Max) | 0 (installed) / 6 (max) |
Manufacturer Warranty | |
Service & Support | Limited warranty - replacement - lifetime - response time: next business day |
Miscellaneous | |
MTBF | 4,113,900 hours |
Compliant Standards | IEC 60950-1, UL 60950-1 Second Edition, WEEE, NOM-019-SCFI-1998, EN 60950-1:2006, EN 300 386 V1.6.1, EN 61000-3-3:2013, EN 61000-3-2:2014, AS/NZS 60950-1:2011, EN 55024:2010+A1:2015, ICES-003:2016 issue 6 Class A, EN 55032:2015 Class A, CISPR 24:2010+A1:2015, CNS13438:2006 Class A, GB 4943-95, KN35:2015, IEC 60320, TCVN 7317:2003, CAN/CSA-C22.2 No. 60950-1-07, EN 55032:2012/AC:2013 Class A, 47 CFR Part 15 Class A, KN32:2015 Class A, TCVN 7189: 2009 Class A, CISPR 32 Second Edition Class A, V-2/2015.04 Class A, V-3/2015.04 Class A |
Power | |
Power Device | Internal power supply - hot-plug |
Installed Qty | 2 |
Max Supported Qty | 4 |
Power Redundancy | Optional |
Power Redundancy Scheme | N+1 (with optional power supply) |
Power Provided | 2000 Watt |
Voltage Required | AC 90-140/180-264 V (47 - 63 Hz) |
Environmental Parameters | |
Min Operating Temperature | 23 °F |
Max Operating Temperature | 113 °F |
Humidity Range Operating | 10 - 95% RH (non-condensing) |
Min Storage Temperature | -40 °F |
Max Storage Temperature | 167 °F |
Dimensions & Weight | |
Width | 17.4 in |
Depth | 16.1 in |
Height | 13.9 in |