Middle Atlantic - Middle Atlantic NEXSYS Series UPS Backup Power System with RackLink

2000VA, 20 Amp - UPS (rack-mountable) - AC 120 V - 1800 Watt - 2000 VA - 4 x battery - Sealed Lead Acid (SLA) - 9 Ah - RS-232, USB, RJ-45 - output connectors: 8 - 2U - 19" - 6 ft cord - black

Middle Atlantic
UPX-RLNK-2000R-2
N/A
0656747395628
N/A
New

Price: $1,705.00

Total Available: 0

Product Description

Additional Details

What's Included

Specifications

Main Specifications
Product Description Middle Atlantic NEXSYS Series UPS Backup Power System with RackLink - 2000VA, 20 Amp - UPS - 1800 Watt - 2000 VA - Sealed Lead Acid (SLA) - 9 Ah
Device Type UPS - rack-mountable
Cord Length 6 ft
Rack Size 19" - 2U
Weight 63.05 lbs
Input Voltage AC 120 V
Output Voltage AC 120 V
Power Capacity 1800 Watt / 2000 VA
Input Connectors 1 x power NEMA 5-20
Output connectors 8 x power NEMA 5-20
Battery Sealed Lead Acid (SLA) - 9 Ah
Batteries Qty 4
Run Time (Up To) 3 min at full load
Networking RS-232, USB, RJ-45
Remote Management Protocol Telnet, SNMP 3, HTTP, HTTPS, SSH, RADIUS
Color Black
Dimensions (WxDxH) 19 in x 22 in x 3.5 in
Environmental Standards ENERGY STAR
Manufacturer Warranty 3-year warranty
General
Device Type UPS - rack-mountable
Height (Rack Units) 2U
Rack Size 19"
Cord Length 6 ft
Color Black
Expansion / Connectivity
Interfaces 1 x management (RS-232) ¦ 1 x management (USB) - 4 pin USB Type B ¦ 2 x management - RJ-45 ¦ 2 x dry contact - terminal block ¦ 1 x EPO (emergency power off) - terminal block
Manufacturer Warranty
Service & Support Limited warranty - 3 years ¦ Limited warranty - batteries - 2 years
Miscellaneous
Cables Included Power cable 6 ft
Features Hot-swappable battery, audible alarm, LCD display, Automatic Voltage Regulation (AVR), Metal Oxide Varistor Technology (MOV), fault alarm, low battery alarm, overload alarm, EBM - External Battery Module - Auto Detection
Compliant Standards FCC Class A certified, CSA, UL 1778, RoHS, cTUVus, REACH
Networking
Remote Management Interface RS-232, USB, RJ-45
Remote Management Protocol Telnet, SNMP 3, HTTP, HTTPS, SSH, RADIUS
Environmental Parameters
Min Operating Temperature 32 °F
Max Operating Temperature 104 °F
Humidity Range Operating 0 - 95% (non-condensing)
Sound Emission 50 dB
Battery
Quantity 4
Technology Sealed Lead Acid (SLA)
Voltage Provided 48 V
Capacity 9 Ah
Run Time (Up To) 3 min at full load ¦ 10 min at half load
Recharge Time 6 hours
Transfer Time 10 ms
Power Device
UPS Technology Line interactive
Input Voltage AC 120 V
Input Voltage Range AC 80 - 158 V
Frequency Required 50/60 Hz
Input Connectors 1 x power NEMA 5-20
Power Output Connectors Details 8 x power NEMA 5-20
Output Voltage AC 120 V
Max Electric Current 20 A
Power Capacity 1800 Watt / 2000 VA
Output Waveform Sinewave
Surge Suppression Yes
Surge Energy Rating 1000 Joules
Circuit Protection Circuit breaker
Power Factor (PF) 0.9
Dimensions & Weight
Width 19 in
Depth 22 in
Height 3.5 in
Weight 63.05 lbs
Dimensions & Weight (Shipping)
Shipping Weight 70.99 lbs
Sustainability Information
ENERGY STAR Yes

Related Products

Below are the optional products related to the selected product.

Suggested Items