Business ContactBrownie & Cookie
Top Links
Power array - AC 200-240 V - 9 kW - 10000 VA - 9 Ah - Ethernet 10/100, RS-232 - output connectors: 16 - black - CTO
Main Specifications | |
---|---|
Product Description | Eaton 9155 - power array - 9 kW - 10000 VA |
Device Type | Power array - external |
Weight | 352.74 lbs |
Input Voltage | AC 200-240 V |
Output Voltage | AC 120 V ± 1% |
Power Capacity | 9 kW / 10000 VA |
Input Connectors | Hardwire |
Output connectors | 16 x power NEMA 5-15R - 120 V |
Battery | Lead acid expandable - 9 Ah |
Batteries Qty | 32 |
Run Time (Up To) | 8.4 min at full load |
Networking | Ethernet 10/100, RS-232 |
Remote Management Protocol | SNMP, Telnet, HTTP, TFTP, SSH, SMTP, DHCP |
Color | Black |
Pricing Type | CTO |
Dimensions (WxDxH) | 12 in x 33.7 in x 32.2 in |
Manufacturer Warranty | 2-year warranty |
General | |
Device Type | Power array - external |
Color | Black |
Expansion / Connectivity | |
Interfaces | 1 x management (RS-232) - 9 pin D-Sub (DB-9) ¦ 1 x EPO (emergency power off) ¦ 2 x monitoring ¦ 4 x management (Fast Ethernet) - RJ-45 ¦ 1 x management (RS-232) - RJ-45 |
Expansion Slots | 2 (total) / 1 (free) x X-Slot |
Manufacturer Warranty | |
Service & Support | Limited warranty - parts - 2 years |
Miscellaneous | |
Cables Included | Serial cable - external |
Equipment Protection Value | 250000 US Dollars |
Features | Advance Battery Management (ABM), audible alarm, emergency power off, LCD display, Parallel Capability, built-in maintenance bypass, internal bypass, LED indicators, generator compatible |
Compliant Standards | UL, VCCI, EN55022, ICES-003, UL 1778, EN55024, EMC, cULus, ISO 9001:2008, ISO 14001:2004, FCC CFR47 Part 15 A, IEC 62040-1:2008+A1, EN 50091-2 Class A |
Pricing Type | CTO |
Networking | |
Remote Management Interface | Ethernet 10/100, RS-232 |
Remote Management Protocol | SNMP, Telnet, HTTP, TFTP, SSH, SMTP, DHCP |
Environmental Parameters | |
Min Operating Temperature | 50 °F |
Max Operating Temperature | 104 °F |
Humidity Range Operating | 0 - 95% (non-condensing) |
Sound Emission | 53 dBA |
Battery | |
Type | Expandable |
Quantity | 32 |
Technology | Lead acid |
Capacity | 9 Ah |
Run Time (Up To) | 8.4 min at full load ¦ 22.4 min at half load ¦ 9.1 min at 8550 Watts ¦ 9.9 min at 8100 Watts ¦ 10.8 min at 7650 Watts ¦ 11.9 min at 7200 Watts ¦ 13.1 min at 6750 Watts ¦ 14.6 min at 6300 Watts ¦ 16.3 min at 5850 Watts ¦ 18.4 min at 5400 Watts ¦ 20.1 min at 4950 Watts ¦ 25.2 min at 4050 Watts ¦ 28.6 min at 3600 Watts ¦ 32.8 min at 3150 Watts ¦ 38.3 min at 2700 Watts ¦ 45.6 min at 2250 Watts |
Transfer Time | 0 ms |
Features | Maintenance free, sealed |
Power Device | |
UPS Technology | On-line |
Input Voltage | AC 200-240 V |
Input Voltage Margin | + 10% / - 15% |
Frequency Required | 45 - 65 Hz |
Input Connectors | Hardwire |
Power Output Connectors Details | 16 x power NEMA 5-15R - 120 V |
Output Voltage | AC 120 V ± 1% |
Power Capacity | 9 kW / 10000 VA |
Output Waveform | Sinewave |
Surge Suppression | Yes |
Circuit Protection | Circuit breaker |
Efficiency | 91% |
Power Factor (PF) | 0.99 |
Total Harmonic Distortion (THD) | 5 % |
Dimensions & Weight | |
Width | 12 in |
Depth | 33.7 in |
Height | 32.2 in |
Weight | 352.74 lbs |