Server Technology - Server Technology PRO3X Switched PDU C3S36RL-GPJE2MT2
Power distribution unit (rack-mountable) - AC 230/240/400/415 V - 17.3 kW - 3-phase WYE (star) - Ethernet 10/100/1000 - input: IEC 60309 3P+N+G - output connectors: 36 (18 x IEC 60320 C13, 18 x IEC 60320 Cx) - 0U - 10 ft cord
Server Technology
C3S36RL-GPJE2MT2
N/A
N/A
New
Price: $2,434.01
MSRP: $2,106.00
Discount off MSRP: -15.58%
Total Available: 1
Product Description
Additional Details
What's Included
Main Specifications | |
---|---|
Product Description | Server Technology PRO3X Switched PDU C3S36RL-GPJE2MT2 - power distribution unit - 17.3 kW |
Device Type | Power distribution unit - rack-mountable |
Cord Length | 10 ft |
Rack Size | 0U |
Input Wiring | 3-phase WYE (star) |
Input Voltage | AC 230/240/400/415 V |
Output Voltage | AC 415 V |
Power Capacity | 17.3 kW |
Input Connectors | 1 x power IEC 60309 3P+N+G |
Output connectors | 18 x power IEC 60320 C13 ¦ 18 x power IEC 60320 Cx |
Networking | Ethernet 10/100/1000 |
Remote Management Protocol | Telnet, SNMP 3, SNMP 2c, HTTP, HTTPS, SSH, SSH-2, CLI, SFTP, SMTP, IPv4, IPv6, TACACS+, LDAP, RADIUS |
Dimensions (WxDxH) | 2.2 in x 2.5 in x 70 in |
General | |
Device Type | Power distribution unit - rack-mountable |
Height (Rack Units) | 0U |
Cord Length | 10 ft |
Expansion / Connectivity | |
Interfaces | 2 x management (Gigabit Ethernet) - RJ-45 ¦ 1 x sensor - RJ-45 ¦ 1 x AUX ¦ 1 x modem - RJ-45 ¦ 1 x USB - 4 pin USB Type A ¦ 1 x USB - 4 pin USB Type B |
Miscellaneous | |
Cables Included | Power cable 10 ft |
Features | LCD display, thermal monitoring, voltage monitoring, humidity monitoring, active power meter, energy meter, power factor meter, Per Input Power Sensing (PIPS), High Density Outlet Technology (HDOT), switched, apparent power meter, hot-swappable controller, Branch Circuit Protection, Ramlock Locking Outlets |
Compliant Standards | EMC, RoHS, WEEE, UL 489, cTUVus, TUV T, Directive 2011/65/EU, FCC Part 15 B 15.109A, EN 55024:2010, EN 55032:2012, CAN/CSA-C22.2 No. 60950-1-07+A1:2011+A2:2014, FCC Part 15 B 15.107A, EN 60950-1:2006+A11+A1+A12+A2, UL 60950-1:2007 R10.14 |
Networking | |
Remote Management Interface | Ethernet 10/100/1000 |
Remote Management Protocol | Telnet, SNMP 3, SNMP 2c, HTTP, HTTPS, SSH, SSH-2, CLI, SFTP, SMTP, IPv4, IPv6, TACACS+, LDAP, RADIUS |
Environmental Parameters | |
Min Operating Temperature | 32 °F |
Max Operating Temperature | 140 °F |
Humidity Range Operating | 8 - 90% (non-condensing) |
Power Device | |
Input Voltage | AC 230/240/400/415 V |
Input Wiring | 3-phase WYE (star) |
Input Connectors | 1 x power IEC 60309 3P+N+G |
Power Output Connectors Details | 18 x power IEC 60320 C13 ¦ 18 x power IEC 60320 Cx |
Output Voltage | AC 415 V |
Max Electric Current | 32 A |
Power Capacity | 17.3 kW |
Circuit Protection | Circuit breaker |
Dimensions & Weight | |
Width | 2.2 in |
Depth | 2.5 in |
Height | 70 in |