Help

Tripp Lite - Eaton Tripp Lite Series SmartOnline 1500VA 1350W 120V Double-Conversion Sine Wave UPS

8 Outlets, Extended Run, Network Card Option, LCD, USB, DB9, 2U Rack/Tower Battery Backup - UPS (rack-mountable) - 12 A - AC 100/110/115/120/127 V - 1.35 kW - 1500 VA - RS-232, USB - output connectors: 6 - 2U - 19"

Tripp Lite
SU1500RTXLCD2U
0037332168610
N/A
New

Price: $1,760.62

MSRP: $1,853.28
Total Available: 24

Product Description

Additional Details

What's Included

Specifications

Main Specifications
Product Description Eaton Tripp Lite Series SmartOnline 1500VA 1350W 120V Double-Conversion Sine Wave UPS - 8 Outlets, Extended Run, Network Card Option, LCD, USB, DB9, 2U Rack/Tower Battery Backup - UPS - 1.35 kW - 1500 VA
Device Type UPS - rack-mountable
Rack Size 19" - 2U
Weight 45.19 lbs
Input Voltage AC 100/110/115/120/127 V
Output Voltage AC 100/110/115/120/127 V ± 2%
Power Capacity 1.35 kW / 1500 VA
Input Connectors Power NEMA 5-15
Output connectors 6 x power NEMA 5-15
Battery Form Factor Plug-in module
Run Time (Up To) 5.8 min at full load
Networking RS-232, USB
Dimensions (WxDxH) 17.5 in x 18.5 in x 3.5 in
Manufacturer Warranty 2-year warranty
General
Device Type UPS - rack-mountable
Battery Enclosure Type Plug-in module
Height (Rack Units) 2U
Rack Size 19"
Expansion / Connectivity
Interfaces 1 x management (USB) - 4 pin mini-USB Type B ¦ 1 x management (RS-232) - 9 pin D-Sub (DB-9) ¦ 1 x EPO (emergency power off)
Expansion Slots 1 (total) / 1 (free) x expansion slot
Manufacturer Warranty
Service & Support Limited warranty - 2 years
Miscellaneous
Cables Included Power cable - integrated - 10 ft ¦ USB cable - external ¦ Serial cable - external
Rack Mounting Kit Included
Equipment Protection Value 250000 US Dollars
Features Audible alarm, LCD display, voltage monitoring, LED indicators, 6 switchable sockets, overvoltage protection, undervoltage protection, cold-start function, AC frequency monitoring, cooling fan, hot-swappable batteries, no load operation & brown-out protection
Compliant Standards CSA, UL 1778, RoHS, FCC Part 15 A
Networking
Remote Management Interface RS-232, USB
Software / System Requirements
Software Included TrippLite PowerAlert
Environmental Parameters
Min Operating Temperature 32 °F
Max Operating Temperature 104 °F
Humidity Range Operating 0 - 95% (non-condensing)
Sound Emission 45 dBA
Battery
Voltage Provided 48 V
Run Time (Up To) 5.8 min at full load ¦ 14 min at half load
Recharge Time 3 hours
Power Device
UPS Technology On-line
Input Voltage AC 100/110/115/120/127 V
Frequency Provided 50/60 Hz
Frequency Required 50/60 Hz
Input Connectors Power NEMA 5-15
Power Output Connectors Details 6 x power NEMA 5-15
Output Voltage AC 100/110/115/120/127 V ± 2% - 50/60 Hz
Max Electric Current 12 A
Power Capacity 1.35 kW / 1500 VA
Dataline Surge Protection Phone line - RJ-11 ¦ Network - RJ-45
Output Waveform Sinewave
Surge Suppression Yes
Surge Energy Rating 570 Joules
Circuit Protection Circuit breaker
Dimensions & Weight
Width 17.5 in
Depth 18.5 in
Height 3.5 in
Weight 45.19 lbs
Dimensions & Weight (Shipping)
Shipping Width 20 in
Shipping Depth 24 in
Shipping Height 9.5 in
Shipping Weight 57.76 lbs

Related Products