- Components & Accessories
- Power Protection Devices
- Stand-Alone UPS
- Back to Results
Main Specifications
|
---|
Product Description
|
Eaton Tripp Lite Series 750VA 500W 120V Line-Interactive Cloud-Connected UPS with Remote Monitoring - 10 NEMA 5-15R Outlets (5 Surge + 5 Surge and Battery Backup), LCD, 5-15P Plug, Tower - UPS - 500 Watt - 750 VA
|
Device Type
|
UPS - external
|
Rack Size
|
0U
|
Weight
|
17.64 lbs
|
Input Wiring
|
1-phase
|
Input Voltage
|
AC 120 V
|
Output Voltage
|
AC 120 V +9% / -12%
|
Power Capacity
|
500 Watt / 750 VA
|
Input Connectors
|
1 x power NEMA 5-15P
|
Output connectors
|
5 x power NEMA 5-15R (UPS and surge) ¦ 5 x power NEMA 5-15R (surge)
|
Battery
|
Lead acid
|
Run Time (Up To)
|
2.2 min at full load
|
Networking
|
NFC, RJ-45, USB
|
Remote Management Protocol
|
CLI
|
Dimensions (WxDxH)
|
5.9 in x 14.6 in x 7.9 in
|
Environmental Standards
|
ENERGY STAR
|
Manufacturer Warranty
|
3-year warranty
|
General
|
---|
Device Type
|
UPS - external
|
Height (Rack Units)
|
0U
|
Expansion / Connectivity
|
---|
Interfaces
|
1 x management (Ethernet) - RJ-45 ¦ 1 x management (USB) - 24 pin USB-C
|
Manufacturer Warranty
|
---|
Service & Support
|
Limited warranty - 3 years
|
Miscellaneous
|
---|
Cables Included
|
Power cable - integrated - 5 ft
|
Equipment Protection Value
|
250000 US Dollars
|
Features
|
ABS housing, LCD display, brown-out protection, overvoltage protection, audible alarm, Automatic Voltage Regulation (AVR), LED indicators, auto restart, pure sinewave output, controllable load banks, overvoltage correction, undervoltage correction, cold-start function, energy saving green topology, self-test
|
Compliant Standards
|
CSA, ICES, NOM, UL 1778, FCC Part 15 Class B, RoHS
|
Networking
|
---|
Remote Management Interface
|
NFC, RJ-45, USB
|
Remote Management Protocol
|
CLI
|
Environmental Parameters
|
---|
Min Operating Temperature
|
32 °F
|
Max Operating Temperature
|
104 °F
|
Humidity Range Operating
|
0 - 90% RH (non-condensing)
|
Battery
|
---|
Technology
|
Lead acid
|
Voltage Provided
|
DC 12 V
|
Run Time (Up To)
|
2.2 min at full load ¦ 8.3 min at half load
|
Transfer Time
|
4 ms
|
Features
|
Valve-regulated
|
Power Device
|
---|
UPS Technology
|
Line interactive
|
Input Voltage
|
AC 120 V
|
Frequency Provided
|
50/60 Hz
|
Input Wiring
|
1-phase
|
Frequency Required
|
50/60 Hz
|
Input Connectors
|
1 x power NEMA 5-15P
|
Power Output Connectors Details
|
5 x power NEMA 5-15R (UPS and surge) ¦ 5 x power NEMA 5-15R (surge)
|
Output Voltage
|
AC 120 V +9% / -12% - 50/60 Hz
|
Power Capacity
|
500 Watt / 750 VA
|
Output Waveform
|
Sinewave
|
Surge Suppression
|
Yes
|
Surge Energy Rating
|
156 Joules
|
Circuit Protection
|
Circuit breaker
|
Efficiency
|
98.4% at 100% Load
|
Power Factor (PF)
|
0.67
|
Dimensions & Weight
|
---|
Width
|
5.9 in
|
Depth
|
14.6 in
|
Height
|
7.9 in
|
Weight
|
17.64 lbs
|
Dimensions & Weight (Shipping)
|
---|
Shipping Width
|
9.3 in
|
Shipping Depth
|
19.5 in
|
Shipping Height
|
11.7 in
|
Shipping Weight
|
43.74 lbs
|
Sustainability Information
|
---|
ENERGY STAR
|
Yes
|