Server Technology - Server Technology PRO2 Switched POPS C2WG12SM-EPJA2D3
Master - power distribution unit (rack-mountable) - AC 230 V - 7.3 kW - 1-phase - RS-232, Ethernet 10/100/1000 - input: IEC 60309 2P+PE - output connectors: 12 (9 x IEC 60320 C13, 3 x IEC 60320 Cx) - 1U
Server Technology
C2WG12SM-EPJA2D3
N/A
N/A
New
Product Description
Additional Details
What's Included
Main Specifications | |
---|---|
Product Description | Server Technology PRO2 Switched POPS C2WG12SM-EPJA2D3 - Master - power distribution unit - 7.3 kW |
Device Type | Power distribution unit - rack-mountable |
Rack Size | 1U |
Input Wiring | 1-phase |
Input Voltage | AC 230 V |
Output Voltage | AC 230 V |
Power Capacity | 7.3 kW |
Input Connectors | 1 x power IEC 60309 2P+PE |
Output connectors | 9 x power IEC 60320 C13 10 A ¦ 3 x power IEC 60320 Cx 16 A |
Networking | RS-232, Ethernet 10/100/1000 |
Remote Management Protocol | Telnet, SNMP 3, SNMP 2c, HTTP, HTTPS, SSH-2, CLI, SFTP, IPv4, IPv6, TACACS+, LDAP, RADIUS |
Dimensions (WxDxH) | 17.2 in x 11.6 in x 1.8 in |
Manufacturer Warranty | 2-year warranty |
General | |
Device Type | Power distribution unit - rack-mountable |
Height (Rack Units) | 1U |
Expansion / Connectivity | |
Interfaces | 1 x management (Gigabit Ethernet) - RJ-45 ¦ 1 x management (RS-232) - RJ-45 ¦ 2 x sensor ¦ 1 x cascading - RJ-12 |
Manufacturer Warranty | |
Service & Support | Limited warranty - parts and labor - 2 years |
Miscellaneous | |
Rack Mounting Kit | Included |
Features | Horizontal orientation, thermal monitoring, voltage monitoring, humidity monitoring, overcurrent protection, active power meter, energy meter, power factor meter, Per Input Power Sensing (PIPS), Per Outlet Power Sensing (POPS), grounded, High Density Outlet Technology (HDOT), high retention locking outlets, locking outlets, apparent power meter, crest factor meter, hot-swappable controller, Branch Current Monitoring, Auto-Flip Current Display, Branch Circuit Protection |
Compliant Standards | EMC, WEEE, UL 489, TUV T, RoHS 2011/65/EU, EN 55024:2010, EN 55032:2012, EN 60950-1:2006+A11+A1+A12+A2 |
Networking | |
Remote Management Interface | RS-232, Ethernet 10/100/1000 |
Remote Management Protocol | Telnet, SNMP 3, SNMP 2c, HTTP, HTTPS, SSH-2, CLI, SFTP, IPv4, IPv6, TACACS+, LDAP, RADIUS |
Environmental Parameters | |
Min Operating Temperature | 32 °F |
Max Operating Temperature | 140 °F |
Humidity Range Operating | 8 - 90% (non-condensing) |
Power Device | |
Input Voltage | AC 230 V |
Input Wiring | 1-phase |
Input Connectors | 1 x power IEC 60309 2P+PE |
Power Output Connectors Details | 9 x power IEC 60320 C13 10 A ¦ 3 x power IEC 60320 Cx 16 A |
Output Voltage | AC 230 V |
Max Electric Current | 32 A |
Power Capacity | 7.3 kW |
Circuit Protection | Circuit breaker |
Dimensions & Weight | |
Width | 17.2 in |
Depth | 11.6 in |
Height | 1.8 in |