Business Contactmike@cd3k.com
Server Technology - Server Technology PRO2 Switched POPS STV-6509Z
Master - power distribution unit (rack-mountable) - AC 415 V - 17.3 kW - Ethernet 10/100, RS-232 - input: NEMA L22-30P - output connectors: 36 (30 x IEC 60320 C13, 6 x IEC 60320 C19) - North America
Server Technology
STV-6509Z
N/A
N/A
N/A
New
Product Description
Additional Details
What's Included
Main Specifications | |
---|---|
Product Description | Server Technology PRO2 Switched POPS STV-6509Z - Master - power distribution unit - 17.3 kW |
Device Type | Power distribution unit - rack-mountable |
Localization | North America |
Input Voltage | AC 415 V |
Output Voltage | AC 415 V |
Power Capacity | 17.3 kW |
Input Connectors | 1 x power NEMA L22-30P |
Output connectors | 30 x power IEC 60320 C13 15 A ¦ 6 x power IEC 60320 C19 20 A |
Networking | Ethernet 10/100, RS-232 |
Remote Management Protocol | SNMP, Telnet, SNMP 3, SNMP 2c, HTTP, HTTPS, SSH, SSH-2, CLI, SFTP, SMTP, IPv4, IPv6, TACACS+, LDAP, RADIUS |
Dimensions (WxDxH) | 2.2 in x 2.3 in x 70 in |
Manufacturer Warranty | 2-year warranty |
General | |
Device Type | Power distribution unit - rack-mountable |
Localization | North America |
Expansion / Connectivity | |
Interfaces | 1 x management (Ethernet) - RJ-45 ¦ 1 x management (RS-232) - RJ-45 ¦ 2 x sensor ¦ 1 x cascading - RJ-12 |
Manufacturer Warranty | |
Service & Support | Limited warranty - parts and labor - 2 years |
Miscellaneous | |
Features | LED display, thermal monitoring, voltage monitoring, humidity monitoring, current meter, active power meter, energy meter, power factor meter, Per Input Power Sensing (PIPS), PDU Power Pivot, Per Outlet Power Sensing (POPS), Branch Current Monitoring, Auto-Flip Current Display |
Compliant Standards | UL, IEC 60950-1, UL 489, cTUVus, TLS v1.2, UL 248, CAN/CSA-C22.2 No. 60950-1-07+A1:2011+A2:2014, FCC Subpart B 15.107, FCC Subpart B 15.109, UL 60950-1:2007 R10.14 |
Networking | |
Remote Management Interface | Ethernet 10/100, RS-232 |
Remote Management Protocol | SNMP, Telnet, SNMP 3, SNMP 2c, HTTP, HTTPS, SSH, SSH-2, CLI, SFTP, SMTP, IPv4, IPv6, TACACS+, LDAP, RADIUS |
Environmental Parameters | |
Min Operating Temperature | 32 °F |
Max Operating Temperature | 140 °F |
Humidity Range Operating | 8 - 90% (non-condensing) |
Power Device | |
Input Voltage | AC 415 V |
Input Connectors | 1 x power NEMA L22-30P |
Power Output Connectors Details | 30 x power IEC 60320 C13 15 A ¦ 6 x power IEC 60320 C19 20 A |
Output Voltage | AC 415 V |
Max Electric Current | 30 A |
Power Capacity | 17.3 kW |
Circuit Protection | Circuit breaker |
Dimensions & Weight | |
Width | 2.2 in |
Depth | 2.3 in |
Height | 70 in |